Okuma Alarm-C 3744 Chucking miss air


Okuma Alarm-C 3744 Chucking miss air

Code
1->The air circuit for detecting chucking miss is clogged.

The clogging check switch kept ON longer than the preset time.

2->The air circuit for detecting chucking miss is clogged.

Chucking miss PS is ON more than 1[sec], during chuck unclamped.

3->The air circuit for detecting chucking miss is clogged.

The chucking miss PS did not turn OFF within the preset time after the chuck unclamp command.

4->The chucking miss PS for air circuit did not turn ON.
5->The air circuit for detecting chucking miss of setup station is clogged. Chucking miss PS kept ON longer than the preset time.
6->The air circuit for detecting chucking miss of machining station is clogged. Chucking miss PS kept ON longer than the preset time.