Okuma Alarm-C 3888 Chip conveyor faulty


Okuma Alarm-C 3888 Chip conveyor faulty

Code
none->Chip coveyer failed.

If “1” is set at MC USER PARAMETER No.19 CHIP CONVEYER “1. Chip conveyer overload/illegal alarmD” the alarm D 4892 Chip conveyor faulty occurs instead of this alarm.

1->The chip conveyor failed. The chip conveyor alarm/signal (I.0243) kept OFF for a second or longer.
2->Chip coveyer becomes full by cutting tips.

If “1” is set at MC USER PARAMETER No.19 CHIP CONVEYER “1. Chip conveyer N.G. alarm-D” the alarm D 4892 Chip conveyer N.G. occurs instead of this alarm.

3->The running mode of the chip conveyor was not coupling operation mode during machine auto mode.
4->The chip conveyor action signal kept OFF for parameter value.
10->Chip conveyor switch is manual mode.
11->The Coolant lowlevel signal with the chip conveyor coolant tank kept OFF for 1[s] or longer.
12->The drum filter is clogged.
13->In the machine conveyor failed. In the machine conveyor alarm/signal kept OFF for a second or longer.
14->In the state of a local mode, the program end (M02/M30) continuously turned ON more than the frequency set to the parameter.
15->The conveyer rotation detecting switch kept ON or OFF for 10 seconds or longer.
16->The scraper conveyer torque switch kept OFF for 3 seconds or longer.

Measures to Take
4)Confirm a chip conveyor action mode, and condition.
14)Confirm a chip conveyor link mode.

Okuma Alarm-C 3888 Chip conveyor faulty