Okuma Alarm-C 3895 Coolant controller error


Okuma Alarm-C 3895 Coolant controller error

Code
1->The coolant controller alarm/signal (I.025B) kept OFF for a second or longer.
2->The coolant cooler alarm/signal (I.0366) kept OFF for 2 seconds or longer.
3->The coolant controller alarm/signal (I.0366) kept OFF for 2[s] or longer.
4->The coolant controller alarm/signal (I.0350) kept OFF for a second or longer.
5->The coolant cooler alarm signal 1(iCLOCA1/) turned OFF.
6->The coolant cooler alarm signal 2(iCLOCA2/) turned OFF.
7->The coolant cooler alarm/signal kept OFF for 3[s] or longer.

The coolant oil controller motor is put under excessive load.

Probable Faulty Locations
1)Overload for coolant oil controller motor.

Measures to Take
1) Check the motor for coolant oil controller.

Okuma Alarm-C 3895 Coolant controller error