Okuma Alarm-P 0817 MCS error


Okuma Alarm-P 0817 MCS error
An error occurred under the control by MCS.

Index
Axis name or none

Character-string
None

Code
XXZZAAAA
XYZZ: 0
AAAA:
1= Processing does not end within 5 seconds after MCS reset 1.
2= Processing does not end within 5 seconds after MCS reset 2.
3= Processing does not end within 5 seconds after PLC reset processing 1.
4= Processing does not end within 5 seconds after PLC reset processing 2.
X: 1 to 3
X: Channel number
YZZAAAA: Communication error status

Probable Faulty Locations
– Faulty MCS controller
– Faulty servo link on FCP board
– Faulty software

Okuma Alarm-P 0817 MCS error