Okuma Alarm-P 0954 Peripheral processor start


Okuma Alarm-P 0954 Peripheral processor start
An error occured with the PSC board at the state of the NC and no response is returned within a preset time(20s).

Code
XY
X:

A->TFP
B->FCP

Y: Internal sequence counter at start up
X:

1-> Main board No. 1
2-> Main board No. 2
3-> Main board No. 3
4-> Main board No. 4

Y:

1-> Main processor start time-out
2-> Task initialization time-out
4-> Failure in starting task

Probable Faulty Locations
Hardware defect or an error in the initialization data (PBU file data) for each processor

Measures to Take
Check the data of the processor indicated by the alarm code.
Check the hardware.
Find which peripheral processor is defective or read the sequence counter value with the alarm code.