Sinumerik Alarm 10702 Channel %1 NCK protection zone %2 violated during manual mode


Sinumerik Alarm 10702 Channel %1 NCK protection zone %2 violated during manual mode

Parameters:
%1 = Channel number
%2 = Protection zone number

Definitions:
The workpiece-related NCK protection zone has been violated. Note that another tool related protection zone is still active. The workpiece-related protected area can be traversed after a new NC Start.

Reactions:
– Alarm display.
– Interface signals are set.
– Local alarm reaction.

Remedy:
Protection zone can be traversed after a new NC Start.

Program Continuation:
Alarm display showing cause of alarm disappears. No further operator action