Sinumerik Alarm 10704 Channel %1 block %2 protection zone monitoring is not guaranteed


Sinumerik Alarm 10704 Channel %1 block %2 protection zone monitoring is not guaranteed

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
New movements of a geometry axis which have been added could not be allowed for at the time of block preparation. It is therefore not certain that the protection zones will not be violated. This is just a warning message without further reactions.

Reactions:
– Alarm display.
– Interface signals are set.

Remedy:
Take other measures to ensure that the geometry axes motion, including the additional motion, does not violate the protection zones. (The warning comes nevertheless) or exclude additional motions.

Program Continuation:
Alarm display showing cause of alarm disappears. No further operator action