Sinumerik Alarm 10772 Channel %1 block %2 illegal orientation change when activating or deactivating 3D face cutting
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In face milling, no intermediate blocks with pure orientation change are allowed between the activation block and the first correction block or between the last correction block and the deactivation block (3D tool radius compensation).
Reactions:
– Local alarm reaction.
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens