Sinumerik Alarm 10913 Channel %1 block %2 negative feed profile is ignored


Sinumerik Alarm 10913 Channel %1 block %2 negative feed profile is ignored

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The given feed profile is in part negative. However, negative path feed is not allowed. The feed profile is ignored. The specified feed block end value is taken when traversing over the entire block.

Reactions:
– Local alarm reaction.
– Alarm display.

Remedy:
No action is usually necessary. The alarm message indicates an error in the programming, however, and this should be corrected.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 10913 Channel %1 block %2 negative feed profile is ignored