Sinumerik Alarm 10943 Channel %1 block %2 curve table %3: direction reversal of lead value in the block not allowed


Sinumerik Alarm 10943 Channel %1 block %2 curve table %3: direction reversal of lead value in the block not allowed

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table

Definitions:
The conditions for converting a programmed contour to a curve table were not fulfilled in this block.

Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.

Remedy:
Correct the part program and start it again.

Program Continuation:
Clear alarm with the RESET key. Restart part program