Sinumerik Alarm 10948 Channel %1 block %2 curve table %3: position jump at end of period
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
A periodic curve table was defined in which the position of the following axis at the end of the table was different to the position at the start of the table.
Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.
Remedy:
Correct the part program and start it again.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens