Sinumerik Alarm 10949 Channel %1 block %2 curve table %3: missing master axis motion
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
A slave axis motion has been programmed without a master axis motion.
Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.
Remedy:
Correct the part program and start it again.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References