Sinumerik Alarm 12580 Channel %1 block %2 %3 not permissible for assignment in motion synchronous action


Sinumerik Alarm 12580 Channel %1 block %2 %3 not permissible for assignment in motion synchronous action

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol

Definitions:
The variable displayed must not be written in a motion synchronous action. Only selected variables are permitted here, e.g. DO $AA_IW[X]=10 is not allowed.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block

Remedy:
Please inform the authorized personnel/service department.Modify part program.In a motion synchronous action, only certain variables are allowed.E.g. $AA_IM, $AC_DTGPB

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 12580 Channel %1 block %2 %3 not permissible for assignment in motion synchronous action