Sinumerik Alarm 12588 Channel %1 block %2 motion synchronous action: address %3 not allowed
Parameters:
%1 = Channel number
%2 = Block number
%3 = Address
Definitions:
• The specified address cannot be programmed in motion synchronous action. Example:ID = 1 WHENEVER $A_IN[1]==1 DO D3
• The cutting edge from motion synchronous actions cannot be changed.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block
Remedy:
Modify part program.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens