Sinumerik Alarm 12730 Channel %1 block %2 no valid transformation machine data parametrized


Sinumerik Alarm 12730 Channel %1 block %2 no valid transformation machine data parametrized

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The machine data $MC__TRAFO_TYPE_1, $MC_TRAFO_AXES_IN_1[1], $MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block

Remedy:
Enter valid transformation identifier for TRACYL in $MC__TRAFO_TYPE_1 and the rotary axis number in $MC_TRAFO_AXES_IN_1[1] or $MC_TRAFO_AXES_IN_2[1].

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 12730 Channel %1 block %2 no valid transformation machine data parametrized