Sinumerik Alarm 12730 Channel %1 block %2 no valid transformation machine data parametrized
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machine data $MC__TRAFO_TYPE_1, $MC_TRAFO_AXES_IN_1[1], $MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block
Remedy:
Enter valid transformation identifier for TRACYL in $MC__TRAFO_TYPE_1 and the rotary axis number in $MC_TRAFO_AXES_IN_1[1] or $MC_TRAFO_AXES_IN_2[1].
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens