Sinumerik Alarm 14014 Channel %1 selected program %3 not available or will be edited


Sinumerik Alarm 14014 Channel %1 selected program %3 not available or will be edited

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name

Definitions:
The selected part program is not in the NCK memory or the access authorization for the program selection is from a higher level than the current control status. During creation, this program received the protection level of the NC control which was active at the time.As of SW 5, when a program is edited on the MMC, it can no longer be started with NC Start.

Reactions:
– Alarm display.

Remedy:
Reload the program in the NCK memory or check and correct the name of the directory (workpiece overview) and the program (program overview) and reselect.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14014 Channel %1 selected program %3 not available or will be edited