Sinumerik Alarm 14037 Channel %1 block %2 involute: radius invalid


Sinumerik Alarm 14037 Channel %1 block %2 involute: radius invalid

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
With involute interpolation, the programmed radius of the basic circle must be greater than zero.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Modify part program.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14037 Channel %1 block %2 involute: radius invalid