Sinumerik Alarm 14048 Channel %1 block %2 wrong number of revolutions in circle programming


Sinumerik Alarm 14048 Channel %1 block %2 wrong number of revolutions in circle programming

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
In the circle programming, a negative number of full revolutions has been specified.

Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.

Remedy:
Modify part program.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14048 Channel %1 block %2 wrong number of revolutions in circle programming