Sinumerik Alarm 14153 Channel %1 block %2 unknown tool carrier type: %3


Sinumerik Alarm 14153 Channel %1 block %2 unknown tool carrier type: %3

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Tool carrier type

Definitions:
An invalid tool carrier type was specified in $TC_CARR23[]. Only the following are allowed: t, T, p, P, m, M.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– Interpreter stop

Remedy:
Change the tool carrier data.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14153 Channel %1 block %2 unknown tool carrier type: %3