Sinumerik Alarm 14154 Channel %1 block %2 The amount of fine correction in parameter %3 of the orientable tool holder %4 is too large
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Invalid parameter of the orientable toolholder
%4 = Number of the orientable toolholder
Definitions:
The maximum permissible value of the fine correction in an orientable toolholder is limited by the machine data $MC_TOCARR_FINE_LIM_LIN for linear variables, and by the machine data $MC_TOCARR_FINE_LIM_ROT for rotary variables. The alarm can only occur if the setting data $SC_TOCARR_FINE_CORRECTION is not equal to zero.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.
Remedy:
Enter a valid fine correction value.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens