Sinumerik Alarm 14180 Channel %1 block %2 H number is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified H number is not assigned to a tool (ISO_2).
Reactions:
– Local alarm reaction.
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
– NC Stop on alarm at block end.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens