Sinumerik Alarm 14401 Channel %1 block %2 transformation not available


Sinumerik Alarm 14401 Channel %1 block %2 transformation not available

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The required transformation is not available.

Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.

Remedy:
Please inform the authorized personnel/service department.
• Modify part program; program defined transformations only.
• Check MD 24100 TRAFO_TYPE_n (assigns the transformation to part program instructions).

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14401 Channel %1 block %2 transformation not available