Sinumerik Alarm 14415 Channel %1 block %2 tangent control: changeover geometry/channel axis not allowed


Sinumerik Alarm 14415 Channel %1 block %2 tangent control: changeover geometry/channel axis not allowed

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
An assignment change of the geometry axes to channel axes is not permitted with active tangential control.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Change part program and delete active tangential control with TANGDEL.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14415 Channel %1 block %2 tangent control: changeover geometry/channel axis not allowed