Sinumerik Alarm 14753 Channel %1 block %2 motion synchronous actions with illegal interpolation type


Sinumerik Alarm 14753 Channel %1 block %2 motion synchronous actions with illegal interpolation type

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion synchronous action or for the function “Several feeds”.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Modify part program.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14753 Channel %1 block %2 motion synchronous actions with illegal interpolation type