Sinumerik Alarm 14754 Channel %1 block %2 motion synchronous actions and wrong feed type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The active feed type is not allowed for the motion synchronous action or for the function “Several feeds”.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens