Sinumerik Alarm 14760 Channel %1 block %2 auxiliary function of a group programmed repeatedly


Sinumerik Alarm 14760 Channel %1 block %2 auxiliary function of a group programmed repeatedly

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The M and H functions can be divided up as required over machine data in groups in any variation. Auxiliary functions are thus put into groups that mutually preclude several individual functions of one group. Within one group only one auxiliary function is advisable and permissible.

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Please inform the authorized personnel/service department. Only program one help function per help function group. (For the group division, see the machine manufacturer’s programming guide).

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14760 Channel %1 block %2 auxiliary function of a group programmed repeatedly