Sinumerik Alarm 14761 Channel %1 block %2 motion synchronous action: DELDTG function not allowed with active tool radius compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Rapid delete distance-to-go for synchronous actions is not allowed with DELDTG when tool radius compensation is active.
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
• Deactivate tool radius compensation before performing rapid delete distance-to-go and then reselect or
• as of SW 4.3: “Delete distance-to-go without preparation”.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens