Sinumerik Alarm 14763 Channel %1 block %2 too many link variables programmed


Sinumerik Alarm 14763 Channel %1 block %2 too many link variables programmed

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The number of NCU link variables programmed exceeds the maximum limit. The number is defined in MD $MC_MM_NUM_LINKVAR_ELEMENTS.

Reactions:
– Alarm display.
– Interface signals are set.
– NC Stop on alarm.
– Interpreter stop
– NC Start disable in this channel.

Remedy:
Modify part program or machine data.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 14763 Channel %1 block %2 too many link variables programmed