Sinumerik Alarm 15166 Channel %1 user system asup _N_ASUP_SPF not available


Sinumerik Alarm 15166 Channel %1 user system asup _N_ASUP_SPF not available

Parameters:
%1 = Channel number

Definitions:
By means of the machine data 11610 $MN_ASUP_EDITABLE the function “User-defined system asup” has been activated. However, the relevant user program could not be found in the specified search path:
• 1. /_N_CUS_DIR/_N_ASUP_SPF
• 2. /_N_CUS_DIR/_N_ASUP_SPF
The default system asups are used.

Reactions:
– Alarm display.
– Interface signals are set

Remedy:
Load the user-defined system asup in /_N_CUS_DIR/_N_ASUP_SPF or /_N_CMA_DIR/_N_ASUP_SPF laden.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 15166 Channel %1 user system asup _N_ASUP_SPF not available