Sinumerik Alarm 15185 Channel %1 %2 errors in INI file
Parameters:
%1 = Channel number
%2 = Number of detected errors
Definitions:
Errors were found when processing initialization programs (INI files), GUD or macro defi- nition files (DEF files).
Reactions:
– Alarm display.
– Interface signals are set.
– NC Start disable in this channel.
Remedy:
Please inform the authorized personnel/service department. Correct the INI or DEF file or correct the MD and create a new INI file (via “Upload”).
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens