Sinumerik Alarm 15300 Channel %1 block %2 invalid number-of-passed-blocks during block search
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the function “Block search with calculation” a negative number of passes has been entered in column P (number of passes). The permissible range of values is P 1 – P 9 999.
Reactions:
– Alarm display.
Remedy:
Enter only positive number of passes within the range of values.
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens