Sinumerik Alarm 15320 Channel %1 block %2 invalid block search command


Sinumerik Alarm 15320 Channel %1 block %2 invalid block search command

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in column type of the block search window. The following block search orders are allowed.
Type Meaning
1 Search for block number
2 Search for label
3 Search for string
4 Search for program name
5 Search for line number in a file

Reactions:
– Alarm display.

Remedy:
Modify the block search command.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens