Sinumerik Alarm 16790 Channel %1 block %2 Parameter is zero or missing


Sinumerik Alarm 16790 Channel %1 block %2 Parameter is zero or missing

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
A coupling has been switched on in which a relevant parameter has been specified with zero or has not been written (e.g. denominator in the transmission ratio, no slave axis).

Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.

Remedy:
Please inform the authorized personnel/service department. • Configure link accordingly in MD (channel MD: 42300 COUPLE_AXIS_n) • or modify part program.

Program Continuation:
Clear alarm with NC START or RESET key and continue the program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 16790 Channel %1 block %2 Parameter is zero or missing