Sinumerik Alarm 17000 Channel %1 block %2 maximum number of symbols exceeded


Sinumerik Alarm 17000 Channel %1 block %2 maximum number of symbols exceeded

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
The maximum number of symbols defined by machine data 28020 MM_NUM_LUD_NAMES_TOTAL has been exceeded.

Reactions:
– Alarm display.
– Interface signals are set.
– Interpreter stop
– NC Start disable in this channel.

Remedy:
Please inform the authorized personnel/service department.
• Modify machine data
• Reduce the number of symbols (variables, subroutines, parameters)

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 17000 Channel %1 block %2 maximum number of symbols exceeded