Sinumerik Alarm 17140 Channel %1 block %2 NCK output %3 is assigned to a function via machine data
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = No. of output
Definitions:
The programmed digital/analog output is assigned to an NC function (e.g. software cams).
Reactions:
– Alarm display.
– Interface signals are set.
– Correction block is reorganized.
Remedy:
Please inform the authorized personnel/service department. Use another output or deactivate concurrent NC function via MD.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
References
- Siemens Diagnostics Guide by Siemens