Sinumerik Alarm 17503 Channel %1 block %2 indexing axis %3 with Hirth tooth system and axis not referenced


Sinumerik Alarm 17503 Channel %1 block %2 indexing axis %3 with Hirth tooth system and axis not referenced

Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name

Definitions:
The ‘Hirth tooth system’ function is activated for the indexing axis and the axis is to be traversed although it is not referenced.

Reactions:
– Alarm display.

Remedy:
Reference axis.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens