Sinumerik Alarm 18314 Channel %1 block %2 frame: type conflict


Sinumerik Alarm 18314 Channel %1 block %2 frame: type conflict

Parameters:
%1 = Channel number
%2 = Block number, label

Definitions:
It is not possible to chain global frames and channel-specific frames. The alarm occurs if a global frame is programmed with a channel axis name and no machine axis on this NCU is assigned to the channel axis. Channel-specific frames cannot be programmed with machine axis names if there is no corresponding channel axis on this NCU.

Reactions:
– Alarm display.
– Interface signals are set.
– NC Stop on alarm.
– Interpreter stop
– NC Start disable in this channel.

Remedy:
Modify part program.

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 18314 Channel %1 block %2 frame: type conflict