Sinumerik Alarm 20062 Channel %1 axis %2 already active


Sinumerik Alarm 20062 Channel %1 axis %2 already active

Parameters:
%1 = Channel number
%2 = Axis name, spindle number

Definitions:
The displayed axis is already traversing as a machine axis. Therefore, it cannot be operated as a geometry axis. Traversing of an axis can take place in JOG mode through 2 different interfaces. 1. as a geometry axis: via the channel-specific interface DB 21 – DB 28, DBX12.6 or DBX12.7 2. as a machine axis: via the axis-specific interface DB 31 – DB 48 DBX8.6 or DBX8.7 With the standard machine control panel, it is not possible to operate an axis as machine axis and geometry axis at the same time.

Reactions:
– Alarm display.

Remedy:
Do not start the geometry axis until the traversing motion as machine axis has been concluded.

Program Continuation:
Clear alarm with the Delete key or NC START.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 20062 Channel %1 axis %2 already active