Sinumerik Alarm 20120 Axis %1: too many compensation relations
Parameters:
%1 = Axis name, spindle number
Definitions:
IInterpolatory compensation with tables. For each axis, the maximum number of compensation relationships defined may be no more than the number of axes in the system. In this alarm, the interpolatory compensation in the axis is switched off automatically.
Reactions:
– Alarm display.
– Interface signals are set.
Remedy:
Check table parameters $AN_CEC_OUTPUT_AXIS and correct and/or switch off one or more tables ($SN_CEC_TABLE_ENABLE).
Program Continuation:
Clear alarm with the RESET key. Restart part program
References