Sinumerik Alarm 2140 The actual service switch position forces a SRAM to be cleared at the next Power On (general reset active)


Sinumerik Alarm 2140 The actual service switch position forces a SRAM to be cleared at the next Power On (general reset active)

Definitions:
The initialization switch is currently set to overall reset.This means that the module’s SRAM is deleted with the next module reset.The NC data memory is cleared during this operation.

Reactions:
– Alarm display.
– NC not ready.
– Interface signals are set.

Remedy:
Reset initialization switch to zero.

Program Continuation:
Alarm display showing cause of alarm disappears.No further operator action.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 2140 The actual service switch position forces a SRAM to be cleared at the next Power On (general reset active)