Sinumerik Alarm 2195 Channel %1 axis %2 high-speed punching/nibbling not possible via link
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
An attempt was made to activate high-speed nibbling or punching for an axis programmed on a different NCU than the drive.
Reactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.
Remedy:
High-speed nibbling and punching is only supported on one NCU.
Program Continuation:
Clear alarm with the RESET key in all channels of this mode group.Restart part program.
References