Sinumerik Alarm 27002 Axis %1 test stop is running


Sinumerik Alarm 27002 Axis %1 test stop is running

Parameters:
%1 = Axis number

Definitions:
Proper functioning of the switch-off path is just being tested by setting of the SGE “Test stop selection”.

Reactions:
– Alarm display.

Remedy:
The message serves only for user information. The alarm automatically disappears after expiration of the delay time that is defined in MD $MA_SAFE_PULSE_DIS_CHECK_TIME, and the removal of the SGE “Test stop selection” when the controller detects pulse deletion, i.e., the test is successfully concluded. A successful test can be recognized by the alarm 27001 with the error code 1005 or the alarm 27024.

Program Continuation:
Alarm display showing cause of alarm disappears. No further operator action