Sinumerik Alarm 27096 SPL start not allowed


Sinumerik Alarm 27096 SPL start not allowed

Definitions:
To start the SPL in protected state (MD $MN_PREVENT_SYNACT_LOCK[0,1] not equal 0) Safety Integrated functionality must first be activated for at least one axis (via MD $MA_SAFE_FUNCTION_ENABLE). Without this functionality it is only possible to operate SPL in start-up state.

Reactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Start up axial Safety Integrated functionality or remove the SPL protection via MD $MN_PREVENT_SYNACT_LOCK[0,1].

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 27096 SPL start not allowed