Sinumerik Alarm 28000 NCU link connection to all other NCUs of the link network has been aborted


Sinumerik Alarm 28000 NCU link connection to all other NCUs of the link network has been aborted

Definitions:
All NCUs in the NCU link network exchange data cyclically (sign-of-life). If this alarm occurs, sign-of-life signals have not been received from any other NCUs on the NCU net- work. This fault in the link can have various causes:
• Defective hardware.
• The machine data which configure the NCU link are not the same on all NCUs.
• An identical interpolator cycle time has not been selected on all NCUs.

Reactions:
– Alarm display.
– Interface signals are set.
– NC not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Check the IPO cycle on all the NCUs. If necessary, check NCU link-specific alarms first.

Program Continuation:
Switch control OFF – ON.