Sinumerik Alarm 28012 NCU link: synchronization cycle signal failure %1 times


Sinumerik Alarm 28012 NCU link: synchronization cycle signal failure %1 times

Parameters:
%1 = Number of cycles

Definitions:
Error message of the NCU link module that does not occur at NCU 1. The NCU’s are synchronized via their own NCU-link clock line. A large number of cycle signals are missing. The parameter indicates how many cycles have failed.

Reactions:
– Alarm display.
– Interface signals are set.
– NC not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Check the hardware.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 28012 NCU link: synchronization cycle signal failure %1 times