Sinumerik Alarm 4004 Channel %1 machine data %2 axis %3 defined repeatedly as geometry axis


Sinumerik Alarm 4004 Channel %1 machine data %2 axis %3 defined repeatedly as geometry axis

Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = Axis index

Definitions:
An axis may only be defined once as a geometry axis.

Reactions:
– Alarm display.
– Interface signals are set.
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Correct $MC_GEOAX_ASSIGN_TAB.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4004 Channel %1 machine data %2 axis %3 defined repeatedly as geometry axis