Sinumerik Alarm 4004 Channel %1 machine data %2 axis %3 defined repeatedly as geometry axis
Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = Axis index
Definitions:
An axis may only be defined once as a geometry axis.
Reactions:
– Alarm display.
– Interface signals are set.
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
Remedy:
Correct $MC_GEOAX_ASSIGN_TAB.
Program Continuation:
Switch control OFF – ON.
References