Sinumerik Alarm 4017 Axis container %1, location %2 already used by NCU %3


Sinumerik Alarm 4017 Axis container %1, location %2 already used by NCU %3

Parameters:
%1 = Axis container number
%2 = Axis container location
%3 = NCU number

Definitions:
A multiple reference to the axis container location has been made via the logical axis table (machine data: MN_AXCONF_LOGIC_MACHAX_TAB).With the NCU link, the multiple reference may also have been made by another NCU in the NCU group.
Example:
Container1 location1 was referenced twice incorrectly
• MN_AXCONF_LOGIC_MACHAX_TAB[0] = CT1_SL1
• MN_AXCONF_LOGIC_MACHAX_TAB[6] = CT1_SL1

Reactions:
– Alarm display.
– Interface signals are set.
– NC not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Correct and complete the container location assignments. Check the machine data for the logical axis assignment table (MN_AXCONF_LOGIC_MACHAX_TAB)

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4017 Axis container %1, location %2 already used by NCU %3