Sinumerik Alarm 4025 Axis container %3 switch not allowed: master/slave active channel %1 axis %2
Parameters:
%1 = Channel
%2 = Axis/spindle
%3 = Axis container number
Definitions:
It is not possible to enable axis container switch as a master/slave link is active.
Reactions:
– Alarm display.
– Interface signals are set.
– NC Stop on alarm.
– Interpreter stop
– NC Start disable in this channel.
Remedy:
Abort program with the RESET key. If required, disconnect the master – slave coupling.
Program Continuation:
Clear alarm with the RESET key. Restart part program
References
- Siemens Diagnostics Guide by Siemens