Sinumerik Alarm 4029 Notice: the axial MDs in axis container %1 will be matched on the next power-up
Parameters:
%1 = Axis container number
Definitions:
Message to the user indicating that the machine data of the axes in the axis container will be matched on the next power-up. An axis container allows axes to be exchanged between channels and NCUs. To ensure that no conflicts arise, the axes within the same axis container must have a similar behaviour. The first axis in the axis container determines which machine data have to be the same for the other axis in the axis container.
Reactions:
– Alarm display.
Remedy:
None
Program Continuation:
Clear alarm with the Delete key or NC START.
References
- Siemens Diagnostics Guide by Siemens