Sinumerik Alarm 4182 Channel %1 invalid M auxiliary function number in %2%3, MD reset


Sinumerik Alarm 4182 Channel %1 invalid M auxiliary function number in %2%3, MD reset

Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, MD index

Definitions:
In the specified machine data, a number has been specified for the configuration of an M function which is occupied by the system, and cannot be used for an assignment. (M0 to M5, M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect).The value set by the user has been reset to the default value by the system.

Reactions:
– Alarm display.
– Interface signals are set.
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.

Remedy:
Configure an M function in the specified machine data which is not occupied by the system (M0 to M5, M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect).

Program Continuation:
Clear alarm with the RESET key. Restart part program

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 4182 Channel %1 invalid M auxiliary function number in %2%3, MD reset